Medonic M-series M32 Hematology Analyzers


Medonic M-series M32 hematology analyzers are packed with advanced functions. From doctors’ offices and small labs to medium-sized clinical units, they deliver 22 parameter, 3-part CBCs with outstanding ease-of-use, accuracy and reliability.
- 7-inch touch-sensitive display with landscape-view WVGA color screen.
- Interface design promotes smooth operation and accurate assessment of results.
- Powerful software with simple-to-understand, easy-to-navigate menus.
- Soft lighting plus ergonomic design simplify sample handling.
- Many smart, innovative functions reside inside the cool blue design.
- USB port is evidence of much improved connectivity and communication.
Four Models


Medonic M32B
Even the basic model includes shear-valve technology.

Medonic M32M
Five-sample mixer is ideal for doctors’ offices and small labs.

Medonic M32B
Even the basic model includes shear-valve technology.

Medonic M32M
Five-sample mixer is ideal for doctors’ offices and small labs.
Key Features


Full CBC in about one minute
Three Medonic M-series M32 analyzers include MPA micro-pipette adapter sampling. Simply take a finger prick sample and view the full blood status on the display in about one minute later.

Full CBC in about one minute
Three Medonic M-series M32 analyzers include MPA micro-pipette adapter sampling. Simply take a finger prick sample and view the full blood status on the display in about one minute later.

Accurate results
Every Medonic M-series M32 analyzers comes equipped with a high-precision shear-valve. No other sampling technique collects blood as precisely as a shear valve. It’s a critical part of the measurement that you’ll see reflected in the accuracy of every result you report.

Accurate results
Every Medonic M-series M32 analyzers comes equipped with a high-precision shear-valve. No other sampling technique collects blood as precisely as a shear valve. It’s a critical part of the measurement that you’ll see reflected in the accuracy of every result you report.
Specifications

Model Characteristics | M32B | M32M | M32C | M32S |
Built-in tube mixer | ||||
Micro-pipette adapter (MPA) | ||||
Maintenance-free shear valve | ||||
Pre-dilution mode | ||||
Cap-piercing device | ||||
Autoloader |
Technical Specification | |
Samples per hour | 60 |
No. of parameters | 22 |
Touch screen | Color |
Samples memory | 50,000 |
QC software | Yes |
No. of reagents used | 2 |
Time to result, open tube inlet | ‹50 sec |
Cv WBC: | 1.6% |
Cv RBC: | 0.8% |
Cv MCV: | 0.5% |
Cv HGB: | 0.6% |
Cv PLT: | 2.9% |